Doppler for Vascular Surgery

Minidop ES100VX

Bidop ES100V3

Smartdop 45

Smartdop 30EX

Smartdop XT6 Port

Smartdop XT14 Port

DVM 4500

Vascular Doppler uses high-frequency sound waves to measure the amount of blood flow through your arteries and veins, usually those that supply blood to your arms and legs. Vascular flow studies, also known as blood flow studies, can detect abnormal flow within an artery or blood vessel.

Minidop ES100VX

The ES-100VX Mini Doppler is a cost effective hand held pocket Doppler with integrated speaker for optimal sound sensitivity. Ideal for pedal pulses, systolic pressures and fetal heart sounds.

Features:

vascular doppler
bidop es100v3

Bidop ES100V3

The Bidop ES100V3 is a visual bidirectional vascular pocket Doppler. View a real-time waveform on the LCD and store up to 30 waveforms for later reference or to download to Smart-V-Link vascular software. Options include a PPG probe for toe pressures and Smart-V-Link software.

Features:

Smartdop 45

The Smartdop 45 is a hand-held bidirectional Vascular Doppler with computer interface for lower extremity testing and documentation. It has a simple, single-button operation which locks in the gain and baseline automatically. It has a real-time waveform LCD and integrated printer for documentation required for reimbursement. Options include a PPG module for toe pressures, pulse volume (PV) for Pulse Volume Recordings (PVR) and Smart-V-Link vascular software.

Features:

Smartdop 45
smartdop 30ex

SMARTDOP 30EX

The Smartdop 30EX is a compact bidirectional vascular Doppler with automatic cuff inflator and computer interface. It automatically calculates ABI and TBI results quickly and accurately. It has a real-time waveform LCD and integrated printer for documentation required for reimbursement. Options include a PPG probe for toe pressures, pulse volume (PV) for Pulse Volume Recordings (PVR) and Smart-V-Link vascular software.

Features:

Smartdop XT 6 Port

The Hadeco Smartdop XT is a fully automatic total vascular testing system for ABI and TBI studies that works with a windows software Smart XT Link including automated blood pressure & pulse volume measurement capabilities for up to 6 sites with simple one button operation.

Features:

smartdop xt 6 port
automatic abi, tbi & pvr

Smartdop XT 14 Port

The Hadeco Smartdop XT is a fully automatic total vascular testing system for ABI and TBI studies that works with a windows software Smart-XT-Link including automated blood pressure & pulse volume capabilities for up to 14 sites with simple one-button-operation.

Features:

DVM 4500

Bi-directional Doppler with large colour touchscreen. Windows based simple touch operation. 2 probe combinations for 4, 5, 8, 10, 20MHz, & PPG. 30 waveform memory & USB interface. PDF and DICOM Export available for USB flash memory. Downsized design with high speed CPU & FFT analysis. PPG probe (Option)..

Features:

Bi-directional Doppler DVM 4500

Wave form mode

Velocity range (FFT)

Vessel diameter

Application

Scroll to Top